The floor temperature sensor should not be installed inside the shower area rather on the bathroom floor.
Schluter floor temperature sensor.
Then connect the wires of the floor temperature sensor at the indicated location behind the thermostat.
Replace the thermostat faceplate and tighten the screw at the bottom of the unit.
One sensor is connected to the thermostat while the other is stored in the thermostat electrical box.
Although schluter will extend the warranty from 10 years to 15 years if you do the insulation resistance test.
The thermostat features a 5 ma built in ground fault circuit interrupter gfci with indicator light and includes a floor temperature sensor.
In your scenario you would need 2 zones and 2 t stats.
Schluter ditra heat e rt ditra heat e rt is programmable touchscreen thermostat that allows you control your electric floor warming system any way you want.
Floor temperature sensor test.
Reinstall the front part of the thermostat on the mounting base.
Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads.
Why are two floor temperature sensors provided with the schluter ditra heat system.
If you have set the t stat to read ambient it ignores the floor sensor and adjust the floor using the rooms air temp.
The resistance will vary according to the temperature i e the colder the sensor the higher the resistance.
Floor temperature sensors may not be threaded through the same conduit as the cold lead.
It may be necessary to temporarily secure the splice to the floor with thin set mortar or adhesive hot glue.
After the curb is installed schluter kerdi waterproofing membrane is installed over the ditra heat system on the shower base and all other waterproofing steps must be completed.
Test 4 temperature sensor.
Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
Two sensors are supplied incase one fails in the future you pull the t sat and connect the spare sensor after disconnecting the failed sensor.
Schluter.
The second sensor can be connected in case of damage to the first sensor without.
An insulation resistance test is recommended but not required.
Area rugs are not recommended over the ditra heat system.
The icon blinks and the period number 1 blinks too.
Let s dive into the tests one by one.
Both floor temperature sensors are installed within the tile assembly.
One 1 floor sensor.
Mark where the cold hot splice will be placed cut the ditra heat or ditra heat duo matting and insert the splice.
The power heating cable and floor temperature sensor connections are now complete.